Download (13MB)
Complete catalog
| |
|
Temperature displays |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Type
|
|
Highlights |
Inputs |
Dimensions |
Power supply |
| |
|
[mm] |
|
Codix 531 pdf
|
 |
MIN/MAX value acquisition and data backup in case of Power Off,
Galvanic isolation with protection against incorrect polarity
Screw terminal connection |
PT100, NI100
2, 3 and 4-wire connection |
DIN 48 x 24 |
10 ... 30 V DC |
Codix 532 pdf
|
 |
MIN/MAX value acquisition and data backup in case of Power Off,
Galvanic isolation with protection against incorrect polarity
Screw terminal connection |
Thermocouples J, K
and N with external or internal cold junction compensation |
DIN 48 x 24 |
10 ... 30 V DC |
Codix 551 pdf
|
 |
Big keys for use with gloves
Programmable characteristic curve end points (up to 24 control points)
MIN/MAX value detection,
Display-Hold
Auxiliary power output for measuring transducer/sensor
2, 3 or 4-wire measurement
Optional: with serial interface |
Thermocouples B, E, J, K, N, R, S, T
Resistance thermometer
PT100, PT 1000, Resistance measurement
0 ... 400 Ohm,
0 ... 4000 Ohm,
0 ... + 100 mV,
-100 .... + 100 mV |
DIN 96 x 48
Clearance needed: 83mm only |
10 ... 30 V DC
90 ... 260 V AC |
| |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
Process controllers, temperature controllers |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Type
|
|
Highlights |
Inputs |
Dimensions |
Power supply |
| |
|
[mm] |
|
Codix 553 pdf
|
 |
Big keys for use with gloves
Programmable characteristic curve end points (up to 24 control points)
MIN/MAX value detection,
Display-Hold
Auxiliary power output for measuring transducer/sensor
Optocoupler or relay outputs
Programmable limit values
Optional: with serial interface |
0 ... 20 mA,
4 ... 20 mA, 0 ... 10 V,
2 .... 10 V,
-10 ... +10 V |
96 x 48 |
10 ... 30 V DC
90 ... 260 V AC |
Codix 554 pdf
|
 |
Big keys for use with gloves
Programmable characteristic curve end points (up to 24 control points)
MIN/MAX value detection,
Display-Hold
Auxiliary power output for measuring transducer/sensor
Optocoupler or relay outputs
Programmable limit values
Optional: with serial interface |
Thermocouples B, E, J, K, N, R, S, T
Resistance thermometer
PT100, PT 1000, Resistance measurement
0 ... 400 Ohm,
0 ... 4000 Ohm,
0 ... + 100 mV,
-100 .... + 100 mV |
96 x 48 |
10 ... 30 V DC
90 ... 260 V AC |
Codix 555 pdf
|
 |
Big keys for use with gloves
Programmable characteristic curve end points (up to 24 control points)
MIN/MAX value detection,
Display-Hold
Auxiliary power output for measuring transducer/sensor
Optocoupler or relay outputs
Totalizer and
Programmable limit values
Optional: with serial interface |
0 ... 20 mA,
4 ... 20 mA, 0 ... 10 V,
2 .... 10 V,
-10 ... +10 V |
96 x 48 |
10 ... 30 V DC
90 ... 260 V AC |
Codix 850 pdf
|
 |
Multifunctional, all usual measuring signals can be connected
Limit value monitoring,
Programmable characteristic curve with up to 32 control points
Programmable with serial interface
Analog output |
0 ... 1 V, 0 ... 20 V
-100 .... + 100 mV
-10 .... + 10 V
0 ... 20 mA, 4 ... 20 mA
-20 ... + 20 mA,,
PT100, Ni100,
Thermocouples |
110 x 45 |
18 ... 36 V DC
20 ... 28 V DC
90 ... 253 V DC |
Codix 851 pdf
|
 |
see 850 with additional LCD display and keys for on-site operation
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|